Technical data
Product | Copper wire rod |
---|---|
Dimension | 8 - 16 mm |
Copper grades | ETP / FRHC |
Capacity | approx. 30,000 – 50,000 t/year |
No. of rolling stands | 8 |
Furnace options
Standard system | Special solutions | ||
Furnace type | Shaft melting furnace | Induction furnace | Refining furnace |
Working mode | Continuous melting | Continuous melting | Batch wise charging-melting-refining-casting |
Input material | Copper cathodes and clean scraps | Copper cathodes | Contaminated copper scraps |
Main energy source | Gas | Electric energy | Gas |
Product | ETP copper wire rod | ETP copper wire rod | FRHC copper wire rod |
Benefits
- Reduced CAPEX due to standardized plant design with wheel belt caster
- Low OPEX due to highly efficient modern AC-drive technology and latest gas regulation system with Lambda control of the shaft furnace
- High fuel efficiency shaft furnace with cathode preheating system
- High-end rolling mill with separate individual AC-drives
- Optimized 3D-printed nozzles for cooling line reduce compressed air consumption
- Coiler for high quality standards
- Flexible plant concept with shaft-, induction-, refining-, or combined furnace concepts
- Use of latest digital tools to control and to optimize the process